CTLA8, CTLA-8, CTLA8cytotoxic T-lymphocyte-associated serine esterase 8, Cytotoxic T-lymphocyte-associated antigen 8, IL17, IL-17, IL17A, IL-17A, IL-17Acytotoxic T-lymphocyte-associated protein 8, IL-17CTLA-8
Кот. Нет. :
YB3967HБренд :
YanbiotechПроисхождение продукта :
ChinaОбъем :
96TСпец. :
Human Elisa KitI. Product Information:
This ELISA kit is based on a sandwich enzyme-linked immunosorbent assay (ELISA) format. Each well of the supplied microplate has been pre-coated with a capture antibody directed against Human IL-17A. After adding standards or samples, the target antigen binds to the immobilized antibody. A biotin-labeled detection antibody specific to Human IL-17A is then introduced, followed by an Avidin-Horseradish Peroxidase (HRP) conjugate. Following incubation and a wash step to remove any unbound material, substrate solution is dispensed into the wells. A blue color develops only in wells where Human IL-17A is present, forming a complex with the biotinylated antibody and Avidin-HRP. The reaction is stopped with an acidic solution, changing the color to yellow. Absorbance is measured at 450 nm ± 2 nm, with the optical density (OD) directly proportional to the concentration of Human IL-17A. Sample concentrations are determined by referencing their OD values against a standard curve.
| Cat Number | YB3967H |
| Alternate Names | CTLA8, CTLA-8, CTLA8cytotoxic T-lymphocyte-associated serine esterase 8, Cytotoxic T-lymphocyte-associated antigen 8, IL17, IL-17, IL17A, IL-17A, IL-17Acytotoxic T-lymphocyte-associated protein 8, IL-17CTLA-8 |
| Detection Method | Sandwich |
| Detection Range | 7.81-500pg/mL |
| Uniprot ID | Q16552 |
| Applications | Cancer,Immunology |
| Species | Human |
| Sensitivity | 4.69 pg/mL |
| Standard | 500pg/mL |
| Sample Type | Serum, Plasma and Other biological samples;Sample Volume=100μL |
| Reaction Time | 3.5H |
II.Sample Testing Protocol:
1. Fresh samples without long time storage is recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results.
2. We are only responsible for the kit itself, but not for the samples consumed during the assay. The users should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance.
3. The detection range of the kit is not equivalent to the concentration range ofthe analyte in the sample. It is recommended to consult reference, conduct preliminary experiments, or seek technical support to estimate the concentration of the analyte in your sample. If the analyte concentration in thesample is too high or too low, appropriate dilution or concentration of thesample should be performed.
4. If the sample type is not included in the manual, a preliminary experiment issuggested to verify the validity.
III. Reagent preparation:
1. Bring all reagents to room temperature(18-25℃) before If the kit will not be used up in one assay, please only take out the necessary strips and reagents for present experiment, and store the remaining strips and reagents at required condition.
2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer. Note: if crystals have formed in the concentrate, warm it in a 40℃ water bath and mix it gently until the crystals have completely dissolved.
3. Standard working solution:
① Centrifuge: Centrifuge the standard at 10,000×g for 1 min.
② Add 1mL of Reference Standard &Sample Diluent, let it stand for 10 minand invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 500pg/mL.
③ Serial dilution:Take 7 EP tubes,adding 250μL of reference standard&sample dilution buffer to each tube(The volume can be adjusted based on actual usage,e.g.,500μL/tube). Transfer 250μL of the 500pg/mL standard working solution into the first tube and mix thoroughly to obtain the 250pg/mL standard working solution. Continue the dilution step by step until the second-to-last tube. The last tube will serve as the blank, and no solution should be transferred from the second-to-last tube. The standard working solution should be freshly prepared and used immediately.
4. Biotinylated Detection Ab working solution: Calculate the required amount before the experiment(100μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the Concentrated Biotinylated Detection Ab at 800×g for 1 min, then dilute the 100×Concentrated Biotinylated Detection Ab to 1×working solution with Biotinylated Detection Ab Diluent (Concentrated Biotinylated Detection Ab: Biotinylated DetectionAb Diluent=1:99).
5. HRP Conjugate working solution: Calculate the required amount before theexperiment (100μL/well). In preparation, slightly more than calculated shouldbe prepared. Centrifuge the Concentrated HRP Conjugate at 800×g for 1 min, then dilute the 100×Concentrated HRP Conjugate to 1×working solution with HRP Conjugate Diluent (Concentrated HRP Conjugate:HRP Conjugate Diluent=1:99).
6. Experimental Operation Tips
① Solutions should be added to the bottom of the micro ELISA plate well, avoid touching the inside wall and causing foaming as much as possible.
② Make the tested strips in use immediately after the wash step. Do not allowwells to be dry.
③ After adding the Substrate Reagent. The reaction time can be shortened orextended according to the actual color change, but not more than 30 min.
④ Adding the stop solution should be done in the same order as the substrate solution.
IV. Assay Procedure:

V. Notice:
For Life Science Rearch Only
Авторское право
@ Wuhan Yanbiotech Co., Ltd. Все права защищены
.
ПОДДЕРЖИВАЕМАЯ СЕТЬ
Xml / политика конфиденциальности